Pages

953D Track Loader Monitoring System

The 953D gauge cluster display.
The gauge cluster provides all necessary
information within the operator’s normal
line of sight.
The 953D gauge cluster display includes:
• Four direct reading gauges
• Fifteen alert indicators
• A numeric message display
• Gauge Cluster
Alert indicators. The fifteen alert
indicators used on the 953D are:
1. Reversible fan
2. Water separator
3. Fuel filters plugging
4. Fuel level
5. Engine air filter plugging
6. Machine security system
7. Ether starting aid
8. Warning lamp
9. Parking brake
10. Operator presence
11. Hydraulic lockout
12. Hydraulic oil filter
13. Bucket float
14. Lift kickout/lower kickout
15. Bucket leveler
Gage cluster-self test. The gauge cluster
self-test verifies that the main display
module is operating properly every time
the key start switch is turned from the
“off” to the “on” position.
NOTE – If the machine is not equipped
with Messenger, the numeric display
will show fault codes.
8
Monitoring System
The gauge cluster provides all necessary functions and information within the operator’s
normal line of sight.